8-3-8. HDCAM SAT Signal Level Adjustment
(SRW-5500 only)
m
. This adjustment is required in the 29.97 Hz, 25 Hz and
23.976 Hz modes.
. Because adjustment data is automatically saved in the
NV-RAM on the EQ-94 board when the automatic
adjustment is completed, saving the data is not required.
. Cue up the alignment tape to the time code 00:10:00:00
in advance.
When using the alignment tape not located to the time
code 00:10:00:00, exit the maintenance mode and cue it
up. Then eject the alignment tape once.
Alignment tape:
HR2-1A
1. Set the system to the 29.97 Hz mode referring to
Section 8-1-3.
2. Display the DT/SAT ADJUST menu.
(HOME menu → [SFT] + [DIAG] → [SFT] + [F8]
→ [ALT] → [F5] → DT/SAT ADJUST menu)
(For the DT/SAT ADJUST menu, refer to Section 3-4-
3.)
3. Press the [F6] (HDCAM SAT) key to display the
HDCAM SAT menu.
4. Press the [SET] key.
5. Insert the alignment tape located to the time code
00:10:00:00.
. Adjustment is executed automatically when the
alignment tape is inserted.
. The message "Auto Adjust Complete" will be
displayed and the alignment tape will be ejected
automatically when this automatic adjustment is
completed normally.
6. Change the system to the 25 Hz and 23.976 Hz mode
referring to Section 8-1-3, then perform the steps 2 to
7 again for each mode.
7. Reset the system to the customer setting referring to
Section 8-1-3.
8. Exit the maintenance mode.
SRW-5000/5500

8-3-9. HDCAM SR DT Measurement

m
. This measurement is required in the 23.976 Hz, 24 Hz,
25 Hz, 29.97 Hz, and 30 Hz modes.
. Because measurement data is automatically saved in the
NV-RAM on the EQ-94 board when the automatic
measurement is completed, saving the data is not
required.
. Cue up the alignment tape to the time code 00:10:00:00
in advance.
When using the alignment tape not located to the time
code 00:10:00:00, exit the maintenance mode and cue it
up. Then eject the alignment tape once.
Alignment tape:
HR5-1B
1. Set the system to the 29.97 Hz mode referring to
Section 8-1-3.
2. Display the DT/SAT ADJUST menu.
(HOME menu → [SFT] + [DIAG] → [SFT] + [F8]
→ [ALT] → [F5] → DT/SAT ADJUST menu)
(For the DT/SAT ADJUST menu, refer to Section 3-4-
3.)
3. Press the [F7] (HDSR MES) key to display the HDSR
MES menu.
4. Press the [SET] key.
5. Insert the alignment tape located to the time code
00:10:00:00.
. Measurement is executed automatically when the
alignment tape is inserted.
. The message "Auto Measure Complete" will be
displayed and the alignment tape will be ejected
automatically when this automatic measurement is
completed normally.
6. Change the system to the 23.976 Hz, 24 Hz, 25 Hz,
and 30 Hz mode referring to Section 8-1-3, then
perform the steps 2 to 7 again for each mode.
7. Reset the system to the customer setting referring to
Section 8-1-3.
8. Exit the maintenance mode.
8-9