Removal
1. Shifting the TG-6
Turn the M gear of the gearbox assembly in
the arrow direction to shift the TG-6 to the
position as shown in the figure.
n
The shutter for detecting the threading/
unthreading end will be released from the T
tension regulator assembly by turning the
threading ring assembly.
2. Disconnecting the Flexible Board
Disconnect the flexible board from the connector
CN220 on the DT-47 board.
3. Removing the EQ Harness Retainer
Remove the two screws fixing the EQ harness
retainer and remove the EQ harness retainer.
n
The screw (PWH3 x 8) fixes the EQ harness
retainer with the DT-47 board.
SRW-5000/5500
M gear
Gear box assembly
TG-6
MC sensor assembly
Flexible board
Disconnect the Flexible Board and EQ Harness Retainer
Threading/Unthreading end sensor
Shutter
T tension regulator
assembly
Pinch arm assembly
Shift the TG-6
EQ harness retainer
PWH3 x 8
BVTT3 x 6
CN220
DT-47 board