Sony SRW-5000 Maintenance Manual page 395

Hd digital
Hide thumbs Also See for SRW-5000:
Table of Contents

Advertisement

5. TC Insert Cross-talk Adjustment
1. Insert the Betacam cassette tape that recorded the no
signal to the LAU tracks.
2. Set the audio analyzer as follows:
Function mode: LEVEL
Input filter:
80 kHz LPF
3. Connect the audio analyzer's input to CUE OUT CH2
connector.
4. Press the [F4] (INC TC) key of the HOME menu
several times to set the TC insert editing mode to ON.
5. Press the PLAY button, then press the EDIT button.
6. Adjust the cross-talk level on the audio analyzer.
(Alternately adjust the following adj. points.)
1RV701/AE-31H (A-3)
Adj. points:
1RV703/AE-31H (A-3)
Specification: Minimize
(The level should be less than _18 dBu)
7. Stop the recording, then eject the cassette tape.
LV400
TP401
E500
TP200
TP201
TP500
RV200
S200
E100
T500
RV203
RV201
RV202
S100
RV100
RV103
RV101 RV102
RV500
F
E
D
AE-31H Board (Side A)
SRW-5000/5500
LV600
6
TP601
E600
RV400
5
RV401
TP300
4
RV300
TP400
RV701
RV204
3
TP202
RV703
RV205
RV700
2
TP100
RV702
C
B
A
1
7-3-5. CUE REC System Adjustment/CUE-13/
AE-31H Boards (SRW-5500 only)
Tools
. Audio signal generator:
Tektronix SG5010 or equivalent
. Audio analyzer:
Audio Precision System One/Two or equivalent
. Audio level meter:
Hewlett-Packard HP3400A or equivalent
. Oscilloscope:
Tektronix TDS460A or equivalent
. Frequency counter:
Advantest TR5821 or equivalent
. Extension board: EX-949
. Shorting clip
. Recording tape:
BCT-HD (HDCAM cassette tape)
Preparation
1. Conditions to be kept are:
. Resetting all the switch settings of the CUE-13 board to
the factory settings. (Refer to "7-3-2. Common Prepara-
tion".)
. Extension of the CUE-13 board.
. Opening of the AE-31H board.
. Cleaning the AT head.
. Check of the other settings. (Refer to "7-3-2. Common
Preparation".)
. Warming up of equipment to be used (20 minutes or
more).
7-19