Sony SRW-5000 Maintenance Manual page 306

Hd digital
Hide thumbs Also See for SRW-5000:
Table of Contents

Advertisement

(3) Bend the six claws of the organic EL indica-
tor module as shown in the figure by the
pliers, and remove the OEL holder and OEL
insulating sheet.
n
The OEL holder and OEL insulating sheet are
bonded.
Installation
4. Attaching the Organic EL Indicator
Module
(1) Attach the OEL holder and OEL insulating
sheet to a new organic EL indicator module,
then fix it with six claws of the organic EL
indicator module.
(2) Connect the flexible card wire to the connec-
tor CN1 on the organic EL indicator module.
n
When replacing the flexible card wire, form
the wire as shoun in the figure by hands.
(3) Attach the organic EL indicator module to the
key panel frame, then fix it with two screws.
Tightening torque: 50 x 10
{5.0 kgf.cm}
5. Reattaching the Key Panel Assembly
Reattach the key panel assembly.
(Refer to step 5 in Section 5-26-1.)
6. Reattaching the Rear Cover
Reattach the rear cover.
(Refer to step 4 in Section 5-25.)
Adjustment after Replacement
7. OEL Indication Test
Refer to Section 3-3-3.
[F6] (OEL) of the PANEL CHECK menu
5-100
_2
N.m
Organic EL indicator module
OEL holder
OEL insulating sheet
Claws
Organic EL indicator module
Replace the Organic EL Indicator Module
Precision P2.6 x 5
CN1
Connector surface
Attach the Organic EL Indicator Module
Bonded
Claws
Key panel frame
40 mm
40 mm