Sony SRW-5000 Maintenance Manual page 336

Hd digital
Hide thumbs Also See for SRW-5000:
Table of Contents

Advertisement

Setting
2. Set the Alignment Tape
(1) Press the switch S1002 on the SS-95 board
during power-on to set the reel tables to the S
cassette position.
(Refer to Section 5-1-3.)
(2) Turn off the power.
(3) Set the alignment tape HR2-1B and put a
weight (about 1 kg) onto it.
3. Connect the Oscilloscope
Connect the oscilloscope as follows:
CH-1: TP52/EQ-94 board (CNF CG ENV signal)
CH-2: TP5/EQ-94 board (SWP5 signal)
TRIG: Set CH-2 as TRIG input.
Oscilloscope setting:
CH-1: 100 mV to 200 mV/DIV
CH-2: 5 V/DIV
TIME: 0.5 to 1 ms/DIV
6-6
. Connection of the oscilloscope
CH-1 : TP52/EQ-94 board (CNF CG ENV signal)
CH-2 : TP5/EQ-94 board (SWP5 signal)
TRIG : CH-2
<EQ-94 board, side A>
A
B
C
D
E
F
G
1
TP52
2
<SS-95 board, side A>
A
B
C
D
E
F
G
1
2
H
J
K
L
M
N
P
TP5
H
J
K
L
M
N
P
S1002
Preparation
SRW-5000/5500