Fuel Supply System
Test procedure
-
Switch off ignition.
-
Connect remote control V.A.G 1348/3A with
adapter cable V.A.G 1348/3-2 ⇒ page 20-8.
-
Remove cap from the fuel filler neck.
Important!
Fuel system is pressurised! Place cleaning rags
around the connection point before opening the
system. Then, release pressure by carefully
loosening the connection point.
K -
Disconnect fuel return flow pipe -2- (press
release buttons).
-
Connect auxiliary hose to adapter V.A.G
1318/17 and fit onto the fuel return flow pipe
of the engine and hold in a measuring vessel.
-
Operate remote control for 15 seconds
(press button and hold).
K -
Compare quantity of fuel supplied with spe-
cification.
*)
Minimum delivery cm
**)
Voltage at fuel pump when engine switched
off and pump running (about 2 V less than
battery voltage).
3
/15 s
¡ ¢ £ £
------------
20
------------