3-5-2] Incoming Call Distribution Group-Queuing Time Table - Panasonic KX-TDA50 Programming Manual

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

2.9 [3] Group
Group FWD Call from Extension—Setting
Indicates the current FWD status for incoming intercom calls directed to the incoming call distribution
group (reference only).
Default
Off
Value Range
Off, On
Maintenance Console Location
2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
Programming Manual References
None
Feature Manual References
1.6.6 FWD (Call Forwarding)
Group FWD Call from Extension—Destination
Specifies the forward destination of incoming intercom calls directed to the incoming call distribution
group.
Default
Not stored.
Value Range
Max. 32 digits (consisting of 0–9, *, #, [ ] [Secret] and P [Pause])
Maintenance Console Location
2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
Programming Manual References
None
Feature Manual References
1.6.6 FWD (Call Forwarding)
2.9.10 [3-5-2] Incoming Call Distribution Group—Queuing Time
Table
A Queuing Time Table can contain up to 16 sequences which control how calls waiting in a queue are
handled. A maximum of 64 (with the KX-TDA50/KX-TDA100/KX-TDA200) or 128 (with the KX-
TDA600) Queuing Time Tables can be programmed.
376