Utility-File Transfer Pc To Pbx (Sd Card) - Panasonic KX-TDA50 Programming Manual

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

A new window will be displayed.
4.
Select the Pair Port Test option.
A new window will be displayed. The card you selected in Step 3 will be shown in the Extension
Line Slot No. drop-down list.
5.
From the CO Line Slot No. drop-down list, select the slot number of the CO line card you want
to test.
6.
From the CO Line Port No. drop-down list, select the port number of the CO line you want to test.
7.
Click OK.
The error report will be displayed.
8.
Select an option:
Click Capture if you want to save the displayed information.
1.
2.
Click Cancel to return to the Diagnosis screen.
Network Loopback Test (KX-TDA100/KX-TDA200/KX-TDA600 only) (MPR
Software File Version 3.2000 or later)
Performs a remote loopback test on the PRI23 card.
Notes
To perform this test, it is necessary to set Loopback Test started by Network (MPR
Software File Version 3.2000 or later) in 2.7.14 [1-1] Slot—PRI Port (KX-TDA100/KX-
TDA200/KX-TDA600 only) to "Enable".
The version of the PRI23 card must be 2.000 or later.
To perform a network loopback test
1.
From the Utility menu, select Diagnosis.
2.
Click on the Status cell of the PRI23 card, and set it to "OUS".
3.
Click on the cell showing the card type.
A new window will be displayed.
4.
Select the Loopback Type option.
A new window will be displayed.
5.
Select Point1 or Point2 depending on the type of loopback test you want to perform.
The available selections may vary depending on the hardware version of the card.
6.
Click Apply.
Preparation for the test is complete. The test will start automatically.
7.
After the test is complete, select Release and click Apply.
8.
Click Close to return to the Diagnosis screen.
2.5.2
Utility—File Transfer PC to PBX (SD Card)
Copies PBX system files (program files and data files) from the connected PC to the SD memory card
installed in the PBX. Pre-existing files on the SD memory card are overwritten.
This option is only available at Installer level.
Enter a file name, or select a file to overwrite.
Click Save.
2.5 Utility