Panasonic KX-TDA50 Programming Manual page 674

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

2.17 [11] Maintenance
Programming Manual References
None
Feature Manual References
1.10.4 Local Alarm Information
Daily Test Start Time—Minute
Specifies the minute of the PBX daily self check start time.
Default
0
Value Range
0–59
Maintenance Console Location
2.17.1 [11-1] Main
Programming Manual References
None
Feature Manual References
1.10.4 Local Alarm Information
Error Log for Centralized VM—Network MSW Transmission (Counter)
Enables error information to be logged in the PBX if network message waiting information is deleted
after re-transmission is repeated for the number of times specified in Network MSW Data
Transmission for Centralized VM Feature—Data Re-transmission : Repeat Counter in 2.15.2 [9-
2] Network Data Transmission.
Default
Disable
Value Range
Disable, Enable
Maintenance Console Location
2.17.1 [11-1] Main
Programming Manual References
2.15.1 [9-1] TIE Table—Enhanced QSIG Call Information (Optional SD Card Required)
2.15.2 [9-2] Network Data Transmission—Network MSW Data Transmission for Centralized VM
Feature—Data Re-transmission : Repeat Counter
Feature Manual References
1.13.14 Private Network Features—Centralized Voice Mail
674
PC Programming Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tda100Kx-tda200Kx-tda600

Table of Contents