Default
8 ms
Value Range
8 × n (n=1–5) ms
Maintenance Console Location
2.7.4 [1-1] Slot—Extension Card Property
Programming Manual References
None
Feature Manual References
None
SLT Flash Detection
Enables the PBX to detect the flash signal sent when an SLT user presses the hookswitch or the
Flash/Recall button.
Default
Enable
Value Range
Disable: The PBX disconnects the line to prevent placing the call on hold.
Enable: The PBX places the call on consultation hold.
Maintenance Console Location
2.7.4 [1-1] Slot—Extension Card Property
Programming Manual References
None
Feature Manual References
1.3.7 Call Splitting
Flash Timing - Min.
Specifies the minimum length that a signal sent from an SLT must be for the PBX to recognize it as
a hookswitch flash signal.
Default
112 ms
Value Range
8 × n (n=3–63) ms
2.7 [1] Configuration
PC Programming Manual
91