Panasonic KX-TDA50 Programming Manual page 519

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

Feature Manual References
1.5.1 EFA (External Feature Access)
1.6.2 Flash/Recall/Terminate
Incoming Call Log Memory
Specifies the number of incoming CO line calls that are retained in the PS's Incoming Call Log
memory.
Default
10
Value Range
0–100
Maintenance Console Location
2.10.10 [4-2-1] Portable Station—Extension Settings
Programming Manual References
None
Feature Manual References
1.3.3 Call Log, Incoming
Outgoing Call Log Memory
Specifies the number of telephone numbers dialed by the PS that are retained in the PS's Outgoing
Call Log memory.
Default
5
Value Range
1–100
Maintenance Console Location
2.10.10 [4-2-1] Portable Station—Extension Settings
Programming Manual References
None
Feature Manual References
1.15.1 Redial, Last Number
ISDN Bearer
Selects the ISDN bearer mode. When Automatic is selected, the bearer mode is set automatically
depending on the type of the PS.
2.10 [4] Extension
PC Programming Manual
519

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tda100Kx-tda200Kx-tda600

Table of Contents