4-6
FUEL AND LUBRICATION SYSTEM
INSPECTION
Measure resistance between the terminals when the float is at
the position listed below.
$ 09900-25008: Multi-circuit tester
Float position
Resistance between terminals
4 – 10 Ω
Full
Approx. 38 Ω
1/2
90 – 100 Ω
Empty
If the resistance measured is out of the specification, replace the
gauge assembly with a new one.
27.1 ± 3.5 mm
50.3 mm
73.1 ± 3.5 mm