Removal (Fig. 29)
1. Park the machine on a level surface, lower the cut-
ting units and stop the engine. Remove the key from the
ignition switch.
2. Unlatch hood.
3. Remove bow tie pin (item 7) and yoke pin (item 16)
to allow hood removal.
4. Lift hood assembly from machine.
5. Remove hood components as necessary using Fig-
ure 29 as a guide.
6. Check condition of all seals on hood. Replace dam-
aged or missing seals.
Reelmaster 5010- H
Installation (Fig. 29)
1. Install all removed hood components using Figure
29 as a guide.
2. Position hood assembly to machine and slide tube
ends onto frame brackets.
3. Install yoke pin (item 16) and secure with bow tie pin
(item 7).
4. Latch hood.
Page 6 - 31