General Information; General Information; Operator's Manual; Electrical Drawings - Toro Reelmaster 5010- H Service Manual

Hide thumbs Also See for Reelmaster 5010- H:
Table of Contents

Advertisement

General Information

Operator's Manual

The Operator's Manual provides information regarding
the operation, general maintenance and maintenance
intervals for your Reelmaster machine. Refer to that
publication for additional information when servicing the
machine.

Electrical Drawings

The electrical schematic and wire harness drawings for
Reelmaster 5010- H machines are located in Chapter 9
- Foldout Drawings.

48 VDC Battery Disconnect

CAUTION
Before installing, removing or servicing compo-
nents in the 48 VDC system (e.g. cutting unit mo-
tors, motor/generator), separate the 48 VDC bat-
tery disconnect. This will prevent unexpected
operation of 48 VDC system components.
The 48 VDC battery disconnect is attached to the right
frame rail under the operator seat (Fig. 1). Unplug the
disconnect to make sure that 48 VDC components do
not operate unexpectedly. Apply dielectric grease to the
contact surfaces of the battery disconnect and plug the
battery disconnect back in after service to the 48 VDC
system is completed.
Electrical System
FRONT
1
1. RH frame rail
Page 5 - 2
2
Figure 1
2. 48V battery disconnect
Reelmaster 5010- H