Troubleshooting

CAUTION
Remove all jewelry, especially rings and
watches, before doing any electrical trouble-
shooting or testing. Disconnect the battery
cables unless the test requires battery voltage.

Operator Advisories

If controls are not selected properly to allow certain ma-
chine operations, the InfoCenter indicator light will illu-
minate and an advisory will be displayed on the
InfoCenter Display. Typically, an advisory can be elimin-
ated with a change in controls by the operator.
Advisory numbers, descriptions and reason for advi-
sories are listed in the table on the next page. Some ad-
visories can be caused by several machine settings.
NOTE: Icons that are used on the InfoCenter display
are identified in the Traction Unit Operator's Manual.
Electrical System
For effective troubleshooting and repairs, there must be
a good understanding of the electrical circuits and com-
ponents used on this machine (see Chapter 9 - Foldout
Drawings).
If the machine has any interlock switches by- passed,
they must be reconnected for proper troubleshooting
and safety.
NOTE: Use the InfoCenter Display to test TEC con-
troller inputs and outputs when troubleshooting an elec-
trical problem on your Reelmaster (see InfoCenter
Display in this chapter).
2
3
4
1. Indicator light
2. Advisory number
Page 5 - 18
1
ADVISORY #162
Denied
H
L
Figure 25
3. Advisory description
4. Reason for advisory
Reelmaster 5010- H