Toro Reelmaster 5010- H Service Manual page 162

Hide thumbs Also See for Reelmaster 5010- H:
Table of Contents

Advertisement

Fault Code
28
48 VDC devices (motor/generator and all cut-
ting reel motors) are all off- line
29
48 VDC system (motor/generator and all cut-
ting reel motors) is under voltage
30
48 VDC system (motor/generator and all cut-
ting reel motors) is over voltage
31
48 VDC system (motor/generator and all cut-
ting reel motors) logic voltage are all excessive
32
Cutting unit fault
33
Motor/generator fault
34
Master (TEC controller) fault
37
TEC output current to energize glow relay is
excessive
38
CAN- bus fault for #1 cutting reel motor
39
CAN- bus fault for #2 cutting reel motor
40
CAN- bus fault for #3 cutting reel motor
41
CAN- bus fault for #4 cutting reel motor
42
CAN- bus fault for #5 cutting reel motor
Electrical System
Fault Description
Page 5 - 22
Service Suggestions
Make sure that 48 VDC battery disconnect is
securely plugged in
Check 10A logic relay fuse
Check 48 VDC master fuse (250A maxi fuse)
Check 48 VDC battery system voltage
Check 48 VDC logic relay and circuit wiring
Check isolation module and circuit wiring
Check CAN- bus termination resistors and cir-
cuit wiring
Check 48 VDC battery voltage
Check 48 VDC battery connections
Check internal motor/generator connections
Consider that motor/generator is faulty
Check 48 VDC battery voltage
If engine is running when fault occurred, check
internal motor/generator connections
Consider that motor/generator is faulty
Check 48 VDC battery voltage
If engine is running when fault occurred, check
internal motor/generator connections
Consider that motor/generator is faulty
Contact Toro distributor for cutting unit service
assistance
Contact Toro distributor for motor/generator
service assistance
Contact Toro distributor for TEC service assis-
tance
Check glow relay and circuit wiring
Check CAN- bus connection to #1 motor
Verify battery power exists at #1 motor
Check CAN- bus termination resistors
Check CAN- bus connection to #2 motor
Verify battery power exists at #2 motor
Check CAN- bus termination resistors
Check CAN- bus connection to #3 motor
Verify battery power exists at #3 motor
Check CAN- bus termination resistors
Check CAN- bus connection to #4 motor
Verify battery power exists at #4 motor
Check CAN- bus termination resistors
Check CAN- bus connection to #5 motor
Verify battery power exists at #5 motor
Check CAN- bus termination resistors