Toro Reelmaster 5010- H Service Manual page 166

Hide thumbs Also See for Reelmaster 5010- H:
Table of Contents

Advertisement

Fault Code
72
High temperature warning for #3 cutting unit
73
High temperature warning for #4 cutting unit
74
High temperature warning for #5 cutting unit
Electrical System
Fault Description
Page 5 - 26
Service Suggestions
Let machine cool to lower cutting unit motor
temperature
Open the rear discharge of the cutting unit
Reduce reel speed if possible
Reduce mow speed if possible
If fault does not seem to be related to cutting
load conditions, check 48 VDC ground for #3
cutting unit motor
Consider replacement of #3 cutting unit motor
if this fault continues to occur
NOTE: A faulty sensor will not cause this fault
Let machine cool to lower cutting unit motor
temperature
Open the rear discharge of the cutting unit
Reduce reel speed if possible
Reduce mow speed if possible
If fault does not seem to be related to cutting
load conditions, check 48 VDC ground for #4
cutting unit motor
Consider replacement of #4 cutting unit motor
if this fault continues to occur
NOTE: A faulty sensor will not cause this fault
Let machine cool to lower cutting unit motor
temperature
Open the rear discharge of the cutting unit
Reduce reel speed if possible
Reduce mow speed if possible
If fault does not seem to be related to cutting
load conditions, check 48 VDC ground for #5
cutting unit motor
Consider replacement of #5 cutting unit motor
if this fault continues to occur
NOTE: A faulty sensor will not cause this fault
Reelmaster 5010- H