Parameter
Caller ID Transport Type
[CallerIDTransportType]
Caller ID Type
[CallerIDType]
V.21 Modem Transport Type
[V21ModemTransportType]
V.22 Modem Transport Type
[V22ModemTransportType]
Version 5.4
Determines the device's behavior for Caller ID detection.
[0] Disable = Caller ID is not detected - DTMF digits remain in
the voice stream.
[1] Relay = Caller ID is detected - DTMF digits are erased from
the voice stream.
[3] Mute = Caller ID is detected - DTMF digits are erased from
the voice stream (default).
Defines one of the following standards for detection (FXO) and
generation (FXS) of Caller ID, and detection (FXO) and generation
(FXS) of MWI (when specified) signals:
[0] Bellcore = Caller ID and MWI (default)
[1] ETSI = Caller ID and MWI
[2] NTT
[4] Britain
[16] DTMF ETSI
[17] Denmark = Caller ID and MWI
[18] India
[19] Brazil
Notes:
Typically, the Caller ID signals are generated/detected
between the first and second rings. However, sometimes the
Caller ID is detected before the first ring signal. In such a
scenario, configure RingsBeforeCallerID to 0.
Caller ID detection for Britain [4] is not supported on the
device's FXO ports. Only FXS ports can generate the Caller ID
for Britain [4].
To select the Bellcore Caller ID sub standard, use the
parameter BellcoreCallerIDTypeOneSubStandard. To select
the ETSI Caller ID sub-standard, use the parameter
ETSICallerIDTypeOneSubStandard.
To select the Bellcore MWI sub standard, use the parameter
BellcoreVMWITypeOneStandard. To select the ETSI MWI sub
standard, use the parameter ETSIVMWITypeOneStandard.
If you define Caller ID Type as NTT [2], you need to define the
NTT DID signaling form (FSK or DTMF) using
NTTDIDSignallingForm.
V.21 Modem Transport Type used by the device.
[0] Disable = Disable (Transparent) -- default
[1] Enable Relay = N/A
[2] Enable Bypass.
[3] Events Only = Transparent with Events.
V.22 Modem Transport Type used by the device.
[0] Disable = Disable (Transparent)
[1] Enable Relay = N/A
[2] Enable Bypass = (default)
[3] Events Only = Transparent with Events