ini File Parameter
SASLocalSIPTLSPort
Profile Parameters
CoderName
SIP User's Manual
For a description of this parameter, refer to "Stand-Alone Survivability"
on page 145.
This ini file table parameter defines the device's coder list. This includes
up to five groups of coders (consisting of up to five coders per group)
that can be associated with IP or Tel profiles ('Coder Group Settings'
page in the Web interface -- refer to ''Coder Group Settings'' on page
166). The first group of coders (indices 0 through 4) is the default coder
list and default coder group. The format of this parameter is as follows:
[CoderName]
FORMAT CoderName_Index = CoderName_Type,
CoderName_PacketInterval, CoderName_rate,
CoderName_PayloadType, CoderName_Sce;
[\CoderName]
Where,
Type = Coder name
PacketInterval = Packetization time
Rate = Packetization rate
PayloadType = Payload type
Sce = Silence suppression mode
For example:
[CoderName]
CoderName 0 = g711Alaw64k, 20,,,0;
CoderName 1 = g726, $$, 3, 38, 0;
CoderName 2 = g729, 40, 255, 255, 1;
[\CoderName]
Notes:
This parameter can include up to 25 indices (i.e., five coders per five
coder groups).
The coder name is case-sensitive.
If silence suppression is not defined for a specific coder, the value
defined by the parameter EnableSilenceCompression is used.
The value of several fields is hard-coded according to common
standards (e.g., payload type of G.711 U-law is always 0). Other
values can be set dynamically. If no value is specified for a dynamic
field, a default value is assigned. If a value is specified for a hard-
coded field, the value is ignored.
Only the ptime of the first coder in the defined coder list is declared
in INVITE / 200 OK SDP, even if multiple coders are defined.
If the coder G.729 is selected and silence suppression is enabled
(for this coder), the device includes the string 'annexb=no' in the SDP
of the relevant SIP messages. If silence suppression is set to 'Enable
w/o Adaptations', 'annexb=yes' is included. An exception is when the
remote device is a Cisco gateway (IsCiscoSCEMode).
For a list of supported coders, refer to ''Coders'' on page 121.
To configure the 'Coders' table in the Web interface, refer to
''Coders'' on page 121.
For a description of using ini file table parameters, refer to
''Structure of ini File Table Parameters'' on page 229.