Board LED States

LEDs located on DL.3 fixture boards indicate how the unit is functioning. The following Table lists
LED States, and problems they may indicate.
Location
LED #
Steady Orange
LD1
Red, Green or OFF
Fixture
Slow Flashing Green
Head
Card
LD2
Fast Flashing Green
Red, Green or OFF
Flashing Green
LD1
Flashing Red
Off
Base
Housing
LD2
Green
Card
Red
Steady Orange
LD3
Red, Green or OFF

General Troubleshooting Suggestions

The following table shows general troubleshooting suggestions:
Problem
Won't power on
During certain movements
the fixture motion slows,
missteps or loses position
Powers on but no image
Image appears "clipped off"
at the bottom
314
State
Problem?
No
Yes
No
Maybe
Yes
No
Maybe
Maybe
No
Maybe
No
Yes
• Check the fuse (page 304).
• Verify fixture is plugged in to an appropriately-rated power source (power
ratings are shown on page 360).
• Check power cord wiring
• If you have loosened or tightened anything in the pan and tilt assemblies,
the stepper motors may be out of alignment. Recalibrate pan and tilt motors
by selecting Calibrate Motors button in the Test_Home menu screen.
• Is the mechanical iris closed? If so, check the setting for the Dimmer
parameter, (see Dimmer on page 241.)
• Did you recently change inputs? About 10 seconds are required for an input
change to take effect. However, you might have selected an invalid input
using projector controls.
Try setting the projector back its defaults, (see Reset Screen on page 40.
Or use DMX to exit the projector menu system (see Projector Control on
page 243).
• Make sure a video input is physically attached to the input you selected, and
that the video feed is active.
• This occurs when the iris plate is in the wrong position for the installed lens
and lens shift is not engaged. Standard, Accessory Wide Angle and
Accessory Ultra Long Throw lenses use one position. The Accessory Long
Throw lens use another (see Adjusting the Iris Plate for the Accessory
Long Zoom lens on page 305).
Description
S3 (iris) sensor open
Link communication error
Running system code, normal operation
Running boot code, expecting or updating
firmware
No firmware or power
Normal operation
Updating firmware
No DMX send or received
Receiving DMX
Transmitting DMX
Normal Operation
Link Communication error