Troubleshooting
This chapter describes how to troubleshoot the S12500 switch installation failures.
The power supply system, fans, and cards of an S12500 switch have multiple LEDs, through which you
can locate the failures.

Configuration terminal problems

If the configuration environment setup is correct, the configuration terminal displays booting information
when the switch is powered on. If the setup is incorrect, the configuration terminal displays nothing or
garbled text.
No terminal display
If the configuration terminal displays nothing after the switch is powered on, verify the following items:
The power supply system works properly.
The main processing unit (MPU) works properly.
The console cable has been connected to the console port of the MPU.
If no problem is found, the following reasons may apply:
The console cable is connected to an incorrect serial port (in other words, the serial port in use is not
the one set on the terminal).
The properties of the terminal are incorrect. You must configure the console terminal as follows: set
Bits per second to 9600, Data bits to 8, Parity to None, Stop bits to 1, Flow control to None, and
Terminal Emulation to VT100.
The console cable fails. If the cable fails, you can replace a cable.
Garbled terminal display
If terminal display is garbled, check that the following settings are configured for the terminal, for
example, HyperTerminal:
Baud rate—9,600
Data bits—8
Parity—none
Stop bits—1
Flow control—None
Emulation—VT100