Maintenance and troubleshooting

Power module failure

The switches use removable power modules.
Examine the PWR1 or PWR2 LED of the switch and the LEDs on the power module to identify power
module failure.
For more information about the PWR1 and PWR2 LEDs on the front panel of the switch,
see
Table
For more information about the LEDs on a power module, see H3C PSR250-12A &
PSR250-12A1 Power Modules User Manual.
Symptom
The power module status LEDs are not steady green.
Solution
To resolve the issue:
Verify that the switch power cord is correctly connected.
1.
Verify that the power source meets the requirement.
2.
Verify that the operating temperature of the switch is in an acceptable range and the power
3.
module has good ventilation.
If the issue persists, contact H3C Support.
4.
To replace a power module, see

Fan failure

WARNING!
• If both fan trays fail during operation, replace them within 2 minutes while the switch is operating.
• If one fan tray fails and the ambient temperature is not higher than 27°C (80.6°F), replace the fan
tray within 24 hours. If one fan tray fails and the ambient temperature is higher than 27°C
(80.6°F), replace the fan tray immediately. Make sure the failed fan tray is in position before the
replacement.
To replace a failed fan tray, see

Configuration terminal problems

If the configuration environment setup is correct, the configuration terminal displays booting
information when the switch is powered on. If the setup is incorrect, the configuration terminal
displays nothing or garbled text.

No terminal display

Symptom
The configuration terminal displays nothing when the switch is powered on.
21.
"Installing/removing a power
"Installing/removing a fan
module."
tray."