H3C S12508-AC Installation Manual page 130

H3c s12500 routing switch series installation guide
Hide thumbs Also See for S12508-AC:
Table of Contents

Advertisement

Table 44 Power system ordering guide
Power
Model
supply
mode
PSE9000-A1
AC
PSE9000-D
DC
NOTE:
The AC power frame and power monitoring module are integrated to the chassis of S12500 AC models,
so you do not need to order them. You must order the PEM and AC power modules yourself.
The DC power frame and power monitoring module are integrated to the chassis of S12500 DC models,
so you do not need to order them. You must order the DC power modules yourself (PEM is not needed
for the DC power system).
Table 45 Electrical parameters of power modules
Power
Rated input voltage
module
range
100 VAC to 120 VAC;
50 Hz or 60 Hz
AC power
module
200 VAC to 240 VAC;
50 Hz or 60 Hz
DC power
–48 VDC to –60 VDC
module
Power components
AC power frame
PEM
Power monitoring module
AC power module
DC power frame
Power monitoring module
DC power module
Max input voltage
range
90 VAC to 264
VAC; 47 Hz to 63
Hz
–42 VDC to –72
VDC
120
Configured number
S12508: 1
S12518: 2
One is required for each power frame
One is required for each power frame
S12508: 6 at most
S12518: 12 at most (at least three are required
for each power frame)
S12508: 1
S12518: 2
One is required for each power frame
S12508: 6 at most
S12518: 12 at most
Max
Max output power
input
current
1200 W (100 VAC to 120
VAC)
13.3 A
2000 W (200 VAC to 240
VAC)
60 A
1800 W

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S12518-dcS12508-dcS12518-ac

Table of Contents