Table 6 PEM description
PEM
LSTM2PEMC6 (PEM-C20)

DC power supply

The DC-powered chassis of the S12500 Routing Switch Series use the PSE9000-D DC power supply
system, which comprises DC power frames, DC power modules, and power monitoring modules.
DC power frame
Each DC power frame can have one power monitoring module and up to six DC power modules.
Figure 12 Front view of a DC power frame
(1) to (6) DC power modules
(7) Power monitoring module
NOTE:
Table 2
describes the LED behaviors of the power monitoring module.
A DC power frame has six pairs of wire posts corresponding to power modules 1 to 6, and one
grounding post. The external DC power system supplies power through the six pair of wire posts.
Description
Applied to the 110 V or 220 V
single-phase three-wire AC power
supply system
One PEM provides six standalone
C20 (16A) sockets numbered in
two rows: 1, 3, and 5 in the top
row, and 2, 4, and 6 in the bottom
row, from left to right.
(8) Power monitoring module LEDs
14
Max number of power modules
6 (each C20 socket for one power module)
(9) Power frame switch