H3C S12500X-AF Series Quick Start Manual
H3C S12500X-AF Series Quick Start Manual

H3C S12500X-AF Series Quick Start Manual

Hide thumbs Also See for S12500X-AF Series:

Advertisement

Quick Links

H3C S12500X-AF Switch Series
Quick Start Guide
New H3C Technologies Co., Ltd.
http://www.h3c.com
Document version: 6PW107-20181116

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S12500X-AF Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for H3C S12500X-AF Series

  • Page 1 H3C S12500X-AF Switch Series Quick Start Guide New H3C Technologies Co., Ltd. http://www.h3c.com Document version: 6PW107-20181116...
  • Page 2 The information in this document is subject to change without notice. All contents in this document, including statements, information, and recommendations, are believed to be accurate, but they are presented without warranty of any kind, express or implied. H3C shall not be liable for technical or editorial errors or omissions contained herein.
  • Page 3: Table Of Contents

    Contents Preparing for installation ···································································· 1     ESD prevention ························································································································· 1   Examining the installation site ······································································································· 1   Installation tools and equipment ···································································································· 1 Installing the switch ·········································································· 2     Switch dimensions ····················································································································· 2   Rack requirements ····················································································································· 5  ...
  • Page 4: Preparing For Installation

    As a best practice, reserve a minimum clearance of 1.2 m (3.94 ft) between the switch and walls or other devices. For more information about the installation site requirements, see H3C S12500X-AF Switch Series Installation Guide. Installation tools and equipment...
  • Page 5: Installing The Switch

    Installing the switch Switch dimensions Figure 2 S12516X-AF switch dimensions 30 mm (1.18 in) 931 mm (36.65 in) 845 mm 90 mm (33.27 in) (3.54 in) 12 mm (0.47 in) (1) Fan tray handle (2) Mounting bracket (3) Cable management bracket...
  • Page 6 Figure 3 S12512X-AF switch dimensions (1) Fan tray handle (2) Mounting bracket (3) Cable management bracket Figure 4 S12508X-AF switch dimensions (1) Fan tray handle (2) Mounting bracket (3) Cable management bracket...
  • Page 7 Figure 5 S12504X-AF switch dimensions (with the LSXM104XFAN fan trays) (1) Fan tray handle (2) Mounting bracket (3) Cable management bracket Figure 6 S12504X-AF switch dimensions (with the LSXM104XFANH fan trays) (1) Fan tray handle (2) Mounting bracket (3) Cable management bracket...
  • Page 8: Rack Requirements

    Rack requirements Table 1 Switch dimensions and rack requirements Model Switch dimensions Rack requirements • Height—931 mm (36.65 in) (21 RU) • Width—440 mm (17.32 in) • Total depth—977 mm (38.46 in) 857 mm (33.74 in) for the chassis S12516X-AF 102 mm (4.02 in) from the rear side of the mounting bracket front ear to the management bracket front end...
  • Page 9: Slide Rail Requirements

    Slide rail requirements IMPORTANT: The switch is heavy. Install the switch at the lowest possible position. Attach the required slide rails to the rack before you mount the device in the rack. For more information about attaching slide rails, see the rails installation guide. Before attaching the slide rails, read signs on the slide rails to identify the right and left slide rails and their front and rear ends.
  • Page 10 Figure 7 Installing cage nuts (for the S12516X-AF switch)
  • Page 11 Figure 8 Installing cage nuts (for the S12512X-AF switch)
  • Page 12 Figure 9 Installing cage nuts (for the S12508X-AF switch) Figure 10 Installing cage nuts (for the S12504X-AF switch)
  • Page 13: Mounting The Switch In A Rack

    Mounting the switch in a rack CAUTION: • Remove fan trays, power modules, and filler panels from the switch before moving if you lift the switch manually. Reinstall these components after installing the switch in the rack. • Do not hold the handle of a fan tray, a power module, or a card, or the air vents of the chassis to move the switch.
  • Page 14: Grounding The Switch

    Figure 11 Mounting the S12516X-AF switch in the rack (1) Chassis handle (2) Slide the chassis into the rack (3) Use screws to secure the mounting brackets to the rack Grounding the switch CAUTION: • Grounding the switch reliably is crucial to lightning protection and EMI protection. Ground the switch reliably before you use it.
  • Page 15 Figure 12 Connecting the grounding cable to a grounding strip (S12516X-AF switch) (1) Use the grounding screws to attach the two-hole grounding lug to the grounding point (2) Grounding sign (3) Grounding strip (4) Grounding post (5) Ring terminal (6) Hex nut...
  • Page 16: Installing Frus

    This section describes the installation procedures for the MPUs, LPUs, switching fabric modules, fan trays, and power modules. For the compatibility matrix between these modules and the switch models, see H3C S12500X-AF Switch Series Installation Guide. WARNING! Long-time exposure to strong air flow might cause discomfort. As a best practice, do not stand close to the air outlet vents while the switch is operating.
  • Page 17: Installing Mpus For The S12504X-Af Switch

    As shown by callout 3 in Figure 13, pull the ejector levers of the MPU outward when most part of the MPU is inserted in the slot. Push the MPU until the brakes on its ejector levers touch the slot edges tightly. As shown by callout 4 in Figure 13, continue to push the MPU by its middle part on the front...
  • Page 18: Installing Lpus

    As shown by callout 4 in Figure 14, push the MPU until the handle breaks touch the slot edges tightly. As shown by callout 5 in Figure 14, continue to push the MPU handle until the MPU is secure in position. Fasten the captive screws on the MPU.
  • Page 19: Installing S12500-X Lpus

    CAUTION: To prevent card damage and ensure correct operation, LPUs can only be used with switching fabric modules of the same type. • Type T LPUs have a character T in their card identifier (for example, LSXM1CGQ36TD1). Type T switching fabric modules have a character string of SFT in their card identifier (for example, LSXM1SFT16E1).
  • Page 20 Installing an S12500-X LPU The S12500-X LPU edges and the ejector lever seats on the LPU slots have purple marks. To install an S12500-X LPU: As shown in Figure 16, loosen the captive screws that secure the LPU to the protection box, pull the ejector levers of the LPU outward, and pull out the LPU from the protection box.
  • Page 21: Installing S12500X-Af Lpus

    Figure 17 Installing an S12500-X LPU (S12516X-AF switch) (1) Push the LPU slowly along the guide rails into the slot (2) Pull the ejector levers outward (3) Push the LPU by the middle part on the front panel (4) Pull the ejector levers inward (5) Fasten the captive screws on the LPU Installing S12500X-AF LPUs CAUTION:...
  • Page 22 Installing an LPU with common ejector levers Remove the filler panel from the target LPU slot. The filler panel removal procedure is the same for LPU and MPU slots. You can see callout 1 Figure 13 for reference. Keep the removed filler panel secure for future use. As shown by Figure 18, orient the LPU with the lettering on it upright.
  • Page 23 Figure 18 Installing an S12500X-AF LPU (S12516X-AF switch) (1) Push the LPU slowly along the guide rails into the slot (2) Pull the ejector levers outward (3) Push the LPU by the middle part on the front panel (4) Pull the ejector levers inward (5) Fasten the captive screws on the LPU Installing an LPU with foldable ejector levers Orient the LPU with the lettering on it upright.
  • Page 24 As shown by callout 5 in Figure 19, push the ejector levers inward towards the front panel. As shown by callout 6 in Figure 19, fasten the captive screws to secure the LPU in the chassis. As shown by callout 7 in Figure 19, rotate the ejector levers upward to the vertically closed position.
  • Page 25: Installing Cable Management Brackets

    Installing cable management brackets The cable management brackets are installed on the two sides of the LPU slots. As a best practice, install cable management brackets after you have installed LPUs. As shown in Figure 20, insert the cable management bracket end that has a spring tab into the cable management bracket hole until the bracket has close contact with the hole.
  • Page 26 CAUTION: The S12516X-AF, S12512X-AF, S12508X-AF, and S12504X-AF switches use slots 18 to 23, 14 to 19, 10 to 15, and 6 to 11 for switching fabric modules, respectively. • To use an LSXM1TGS24FX1 LPU, the three lowest-numbered switching fabric module slots take precedence over other slots for module installation.
  • Page 27: Installing A Filler Panel In A Switching Fabric Module Slot

    Figure 21 Removing the switching fabric module from the protection box (S12516X-AF switching fabric module) (1) Five screws to secure the protection box to the switching fabric module (2) Loosen the captive screws (3) Hold the protection box to disengage it from the connector side of the switching fabric module Figure 22 Installing a switching fabric module (S12516X-AF switch) (1) Push the switching fabric module slowly into the slot (2) Rotate the ejector levers inward until the spring clips lock the ejector levers in place...
  • Page 28: Removing A Filler Panel From A Switching Fabric Module Slot

    To install a filler panel in a switching fabric module slot: Loosen the captive screws on the ejector levers and rotate outward the ejector levers. Orient the filler panel with the side marked "Up" facing up. Hold the filler panel front panel near the ejector levers with one hand and support its bottom with the other.
  • Page 29: Installing Fan Trays

    Figure 24 Removing the filler panel from a switching fabric module slot (S12516X-AF switch) (1) Loosen the captive screws on the ejector levers (2) Rotate the ejector levers outward (3) Pull the filler panel out of the slot along the guide rails Installing fan trays Follow these restrictions and guidelines when you install a fan tray: •...
  • Page 30: Installing Fan Trays For The S12516X-Af, S12512X-Af, And S12508X-Af Switches

    Installing fan trays for the S12516X-AF, S12512X-AF, and S12508X-AF switches IMPORTANT: The fan tray is high and heavy. To avoid device damage and bodily injury, use two people to install or remove a fan tray. To install a fan tray for the S12516X-AF/S12512X-AF/S12508X-AF switch: Orient the fan tray with the upside up based on the orientation of characters on the fan tray and align the fan tray with the fan tray slot.
  • Page 31: Installing Fan Trays For The S12504X-Af Switch

    Installing fan trays for the S12504X-AF switch Orient the fan tray correctly. To install a fan tray in the FAN1 slot, orient the fan tray so that the LEDs are on the left side of the front panel. To install a fan tray in the FAN2 slot, orient the fan tray so that the LEDs are on the right side of the front panel.
  • Page 32 The power module is foolproof. If the power module is oriented incorrectly, you cannot install the power module into the slot. If you encounter a hard resistance while inserting the power module, pull out the power module, reorient it, and then insert it again. Figure 27 Removing a filler panel (1) Figure 28 Removing a filler panel (2) Figure 29 Installing a power module (S12516X-AF switch)
  • Page 33: Connecting The Power Cord

    Connecting the power cord CAUTION: • Power on the switch after you have installed fan trays on the switch. • Make sure each power cord has a separate circuit breaker. • Turn off the circuit breaker before you connect the power cord. Connecting an AC power cord Plug the AC power cord connector into the AC input receptacle of the power module.
  • Page 34: (Optional) Installing A Dc Input Terminal Block

    Figure 31 Connecting the DC power cord (Optional) Installing a DC input terminal block You can order an extension cable and a DC input terminal block to supply power to the device if the following situations exist: • The power distribution box is far away from the rack. •...
  • Page 35: (Optional) Installing Transceiver Modules

    As shown in Figure 33, insert the wires of the extension cable into the upper-row terminals on the DC input terminal block, and insert the other ends of the wires into the terminals on the power distribution cabinet. Insert the wires of the DC power cord into the lower-row terminals on the DC input terminal block, and insert the other ends of the wires into the terminal block on the switch.
  • Page 36: Installing A Cfp2 Module

    For an SFP+ module, press the module down so you can push the module straight into the port. If you cannot hold the module by its two sides because of high module density, press the module on its head end to push it in. Figure 34 Installing an SFP+/SFP/QSFP+/QSFP28 module (S12516X-AF switch) Installing a CFP2 module CAUTION:...
  • Page 37: Installing A Cxp Module

    Figure 35 Installing a CFP2 module (S12516X-AF switch) (1) Pivot up the metal handle (2) Push the module gently into the slot Installing a CXP module CAUTION: • Read the following instructions before you install a CXP module. Failure to follow these instructions might cause damage to the CXP module.
  • Page 38: Connecting An Sfp+/Qsfp+/Qsfp28/Qsfp+ To Sfp+ Dac Cable

    To install a CXP module: Unpack the CXP module. Do not touch the golden plating of the module. Correctly orient the CXP module and make sure the pull latch is on top of the CXP module. Gently push the module into the slot until it has firm contact with the slot. Figure 36 Installing a CXP module (S12516X-AF switch) Connecting an SFP+/QSFP+/QSFP28/QSFP+ to SFP+ DAC cable...
  • Page 39: Cabling Recommendations

    Cabling recommendations Routing network cables The cable management brackets are installed on the two sides of the LPU section. As a best practice, route network cables from the left and right sides, as shown in Figure Figure 37 Routing network cables (S12516X-AF switch)
  • Page 40: Accessing The Switch

    Accessing the switch The first time you access the switch you must use a console cable to connect a console terminal, for example, a PC, to the console port on the switch. Connecting the console cable IMPORTANT: • Identify the mark on the console port and make sure you are connecting to the correct port. •...
  • Page 41: Verification Before Login

    Verification before login Before you log in to the switch, perform the following tasks: • Verify that the switch has been correctly installed. • Verify that all cards have been correctly installed. • Verify that all the network cables, fibers, power cables, and grounding cables have been correctly connected.
  • Page 42 The cooling system is working, and you can hear fan rotating noise and feel air being blown out. • The LEDs on the MPUs show that the system is operating correctly. For more information about LEDs, see H3C S12500X-AF Switch Series Installation Guide.

This manual is also suitable for:

S12516x-afS12512x-afS12508x-afS12504x-af

Table of Contents