H3C S12508-AC Installation Manual page 75

H3c s12500 routing switch series installation guide
Hide thumbs Also See for S12508-AC:
Table of Contents

Advertisement

System power-supply policy: enable
System power-module redundant(configured): 1
System power usable: 18000 Watts
System power redundant(actual): 2000 Watts
System power allocated: 2620 Watts
System power available: 15380 Watts
SYSTEM POWER USED(CURRENT): 470.00 Watts
System power monitoring unit:
Software version: 100
Type
In/Out
----------
------
PSE9000
AC/DC
DC output voltage information:
Tray Value(V)
Upper-Threshold(V)
---- --------
------------------
1
50.00
53.00
2
50.00
53.00
DC output current information:
Total current(A): 2.00
Branch
Value(A)
------
--------
1
N/A
2
0.90
3
1.40
4
0.80
5
1.50
6
0.40
7
0.90
8
0.60
9
0.90
10
N/A
11
1.00
12
1.00
PSU Status:
ID Status
Input-Err
-- ------- ----------- ---------- ---------------- ------- ------ -------------
1 Absent
2 Normal
3 Normal
4 Normal
5 Normal
6 Normal
7 Normal
Rated-Vol(V)
Existing
------------
--------
220(default)
10
Lower-Threshold(V)
------------------
47.00
47.00
Output-Err High-Temperature Fan-Err Closed Current-Limit
65
Usable
Redundant(actual)
------
-----------------
9
1
Status
-------
Normal
Normal

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S12518-dcS12508-dcS12518-ac

Table of Contents