H3C S12501X-AF Manual
Hide thumbs Also See for S12501X-AF:

Advertisement

Quick Links

Contents
Installing FRUs ················································································ 1
Attaching an ESD wrist strap ········································································································ 1
Installing MPUs ························································································································· 2
Installing MPUs for the S12516X-AF, S12512X-AF, and S12508X-AF switches ································ 3
Installing MPUs for the S12504X-AF switch ·············································································· 4
Installing MPUs for the S12502X-AF switch ·············································································· 5
Installing LPUs ·························································································································· 6
Installing S12500-X LPUs ····································································································· 7
Installing S12500X-AF LPUs ································································································ 10
Installing an LPU with common ejector levers ·········································································· 11
Installing an LPU with foldable ejector levers ··········································································· 12
Installing cable management brackets ·························································································· 14
Installing switching fabric modules ······························································································· 14
Installing a filler panel in a switching fabric module slot ······························································ 16
Removing a filler panel from a switching fabric module slot ························································ 17
Installing fan trays ···················································································································· 18
Installing fan trays for S12516X-AF, S12512X-AF, and S12508X-AF switches ································ 19
Installing fan trays for an S12504X-AF switch ·········································································· 20
Installing fan trays for an S12502X-AF switch ·········································································· 21
Installing fan trays for an S12501X-AF switch ·········································································· 22
Installing power modules ··········································································································· 23
Connecting the power cord ········································································································ 25
Connecting an AC power cord ······························································································ 25
Connecting a DC power cord ······························································································· 26
(Optional) Installing a DC input terminal block ·········································································· 26
Installing transceiver modules ····································································································· 27
Installing an SFP+/SFP/QSFP+/QSFP28 module ····································································· 28
Installing a CFP2 module ···································································································· 29
Installing a CXP module ······································································································ 30
Connecting a CXP fiber cable ······························································································ 31
Connecting an SFP+/QSFP+/QSFP28/QSFP+ to SFP+ copper cable ·········································· 31
i

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S12501X-AF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for H3C S12501X-AF

  • Page 1: Table Of Contents

    Installing fan trays for S12516X-AF, S12512X-AF, and S12508X-AF switches ································ 19 Installing fan trays for an S12504X-AF switch ·········································································· 20 Installing fan trays for an S12502X-AF switch ·········································································· 21 Installing fan trays for an S12501X-AF switch ·········································································· 22 Installing power modules ··········································································································· 23 Connecting the power cord ········································································································ 25 Connecting an AC power cord ······························································································...
  • Page 2: Installing Frus

    Keep the chassis and the component packages for future use. Attaching an ESD wrist strap An S12501X-AF switch does not have an ESD jack and no ESD wrist strap is provided with it. Prepare an ESD wrist strap for the switch yourself and ground the strap reliably.
  • Page 3: Installing Mpus

    An S12501X-AF switch does not require MPUs. Unless otherwise stated, the term "MPU" in this document refers to MPUs and cloud SEUs.
  • Page 4: Installing Mpus For The S12516X-Af, S12512X-Af, And S12508X-Af Switches

    Installing MPUs for the S12516X-AF, S12512X-AF, and S12508X-AF switches For the S12516X-AF, S12512X-AF, and S12508X-AF switches, the ejector levers of the MPUs and the ejector lever seats on the MPU slots have pink marks. The MPU installation procedure is the same for the S12516X-AF, S12512X-AF, and S12508X-AF switches.
  • Page 5: Installing Mpus For The S12504X-Af Switch

    Installing MPUs for the S12504X-AF switch The S12504X-AF switch MPU marks and MPU slot edges are pink-marked. To install an MPU for the S12504X-AF switch: As shown by callout 1 in Figure 3, remove the filler panel from the target MPU slot. Keep the removed filler panel secure for future use.
  • Page 6: Installing Mpus For The S12502X-Af Switch

    Figure 3 Installing an MPU (S12504X-AF switch) (1) Loosen the captive screws and remove the filler panel (2) Pivot up the handle (3) Push the MPU into the slot along the guide rails (4) Push the MPU until the handle breaks touch the slot edges tightly (5) Push the handle until the MPU is secure in position (6) Fasten the screws on the MPU Installing MPUs for the S12502X-AF switch...
  • Page 7: Installing Lpus

    As shown by callout 4 in Figure 4, close the ejector lever until the latch locks the ejector lever in place. Figure 4 Installing an MPU Installing LPUs CAUTION: • Before you install an LPU on the switch, make sure the connectors on the LPU are not damaged or blocked.
  • Page 8: Installing S12500-X Lpus

    For the compatibility between the switch and the LPUs (also called interface modules), see "Appendix B FRUs and compatibility matrixes." The S12501X-AF and S12502X-AF switches support only S12500X-AF Type H LPUs. Installing S12500-X LPUs The S12500X-AF switch supports only FX and FE series S12500-X LPUs. To install an S12500-X LPU on the switch, first install an interface module adapter in the LPU slot.
  • Page 9 Figure 5 Installing an interface module adapter (S12516X-AF switch) (1) Push the interface module adapter slowly along the guide rails into the slot (2) Fasten the screws to secure the interface module adapter to the chassis Installing an S12500-X LPU The S12500-X LPU edges and the ejector lever seats on the LPU slots have purple marks.
  • Page 10 Figure 6 Removing an S12500-X LPU from the protection box (1) Loosen the captive screws that secure the LPU to the protection box (2) Pull the ejector levers outward (3) Pull the LPU out of the protection box...
  • Page 11: Installing S12500X-Af Lpus

    Installing S12500X-AF LPUs CAUTION: • The S12501X-AF and S12502X-AF switches support only S12500X-AF Type H LPUs. • A protective blank panel is installed over LPU slots on the S12502X-AF to avoid damage during transportation. Before you install an LPU on the S12502X-AF, remove the protective blank panel...
  • Page 12: Installing An Lpu With Common Ejector Levers

    IMPORTANT: Keep filler panels installed on unused LPUs. No interface module adapter is required to install an S12500X-AF LPU on the switch. The S12500X-AF LPU ejector levers and the ejector lever seats on the LPU slots have purple marks. Installing an LPU with common ejector levers As shown by callout 1 in Figure 8, remove the filler panel from the target LPU slot.
  • Page 13: Installing An Lpu With Foldable Ejector Levers

    Figure 8 Installing an LPU with common ejector levers (S12516X-AF switch) (1) Push the LPU slowly along the guide rails into the slot (2) Pull the ejector levers outward (3) Push the LPU by the middle part on the front panel (4) Pull the ejector levers inward (5) Fasten the captive screws on the LPU Installing an LPU with foldable ejector levers...
  • Page 14 As shown by callout 4 in Figure 9, push the LPU by its middle part on the front panel until you cannot move it. As shown by callout 5 in Figure 9, push the ejector levers inward towards the front panel. As shown by callout 6 in Figure 9, fasten the captive screws to secure the LPU in the chassis.
  • Page 15: Installing Cable Management Brackets

    Installing cable management brackets For an S12501X-AF switch, the cable management brackets come attached to the mounting brackets and do not require separate installation. The cable management brackets are installed on the two sides of the LPU slots. As a best practice, install cable management brackets after you have installed LPUs.
  • Page 16 LSXM1SFF16C1). Type F LPUs have a character of F in their card identifier (for example, LSXM1CGP12FX1). The S12501X-AF and S12502X-AF switches do not require switching fabric modules. For the compatibility between the switch and the switching fabric modules, see "Appendix B FRUs and compatibility matrixes."...
  • Page 17: Installing A Filler Panel In A Switching Fabric Module Slot

    until the spring clips lock the ejector levers in place and the switching fabric module is completely seated in the slot. Figure 11 Removing the switching fabric module from the protection box (S12516X-AF switching fabric module) (1) Five screws to secure the protection box to the switching fabric module (2) Loosen the captive screws (3) Hold the protection box to disengage it from the connector side of the switching fabric module Figure 12 Installing a switching fabric module (S12516X-AF switch)
  • Page 18: Removing A Filler Panel From A Switching Fabric Module Slot

    To install a filler panel in a switching fabric module slot: Loosen the captive screws on the ejector levers and rotate outward the ejector levers. Orient the filler panel with the side marked "Up" up. Hold the filler panel front panel near the ejector levers with one hand and support its bottom with the other.
  • Page 19: Installing Fan Trays

    Figure 14 Removing a filler panel from a switching fabric module slot (S12516X-AF switch) (1) Loosen the captive screws on the ejector levers (2) Rotate the ejector levers outward (3) Pull the filler panel out of the slot along the guide rails Installing fan trays WARNING! When removing the fan tray, keep your hands and fingers away from the spinning fan blades.
  • Page 20: Installing Fan Trays For S12516X-Af, S12512X-Af, And S12508X-Af Switches

    • Ensure electricity safety. • For an S12501X-AF switch, you can hot swap a fan tray only when the other two fan trays are operating correctly. For the other S12500X-AF switch models, you can hot swap a fan tray only when the other fan tray is operating correctly.
  • Page 21: Installing Fan Trays For An S12504X-Af Switch

    Figure 15 Installing a fan tray (S12516X-AF switch) (1) Align the fan tray with the fan tray slot (2) Fasten the captive screws Installing fan trays for an S12504X-AF switch Orient the fan tray correctly. To install a fan tray in the FAN1 slot, orient the fan tray so that the LEDs are on the left side of the front panel.
  • Page 22: Installing Fan Trays For An S12502X-Af Switch

    Figure 16 Installing a fan tray for the S12504X-AF switch (1) Align the positioning pin on the fan tray with the positioning hole above the fan tray slot (2) Insert the fan tray into the chassis (3) Fasten the captive screws on the fan tray Installing fan trays for an S12502X-AF switch CAUTION: To install a fan tray in slot FAN1, orient the fan tray so that the LED is on the left side of the front...
  • Page 23: Installing Fan Trays For An S12501X-Af Switch

    Figure 17 Installing a fan tray Installing fan trays for an S12501X-AF switch The following procedure uses the FAN3 slot as an example. To install a fan tray: Unpack the fan tray. As shown by callouts 1 and 2 in Figure 17, orient the fan tray with the Top mark on the top.
  • Page 24: Installing Power Modules

    Figure 18 Installing a fan tray Installing power modules On an S12501X-AF switch, the power module slots are located on the right of the rear panel. On the other S12500X-AF switch models, the power module slots are located on both sides of the rear panel.
  • Page 25 Figure 19 Removing a filler panel (1) Figure 20 Removing a filler panel (2) Figure 21 Installing a power module (S12516X-AF switch)
  • Page 26: Connecting The Power Cord

    • Turn off the circuit breaker before you connect the power cord. Connecting an AC power cord CAUTION: Use AC power cords with straight connectors for an S12501X-AF switch. To connect an AC power cord: Connect the AC power cord connector to the AC input receptacle of the power module.
  • Page 27: Connecting A Dc Power Cord

    Connecting a DC power cord To connect the DC power cord: Connect the DC power cord connector to the DC input receptacle of the power module. Fasten the screw on the connector to secure the connector to the receptacle. Connect the other ends of the DC power cords to terminals of the power source. Figure 23 Connecting the DC power cord (Optional) Installing a DC input terminal block You can order an extension cable and a DC input terminal block to supply power to the device if the...
  • Page 28: Installing Transceiver Modules

    Figure 24 Attaching a DC input terminal block to a rack To connect power wires to a DC input terminal block: As shown in Figure 25, insert the wires of the extension cable into the upper-row terminals on the DC input terminal block, and insert the other ends of the wires into the terminals on the power distribution cabinet.
  • Page 29: Installing An Sfp+/Sfp/Qsfp+/Qsfp28 Module

    Installing an SFP+/SFP/QSFP+/QSFP28 module CAUTION: • Read the following instructions before you install an SFP+/SFP/QSFP+/QSFP28 module. Failure to follow these instructions might cause damage to the SFP+/SFP/QSFP+/QSFP28 module. • Do not remove the dust plug from the SFP+/SFP/QSFP+/QSFP28 module if you are not to connect an optical fiber to the module.
  • Page 30: Installing A Cfp2 Module

    Installing a CFP2 module CAUTION: • Read the following instructions before you install a CFP2 module. Failure to follow these instructions might cause damage. • Do not remove the dust plug from the CFP2 module if you are not to connect an optical fiber to the module.
  • Page 31: Installing A Cxp Module

    Figure 27 Installing a CFP2 module (S12516X-AF switch) (1) Pivot the module handle up (2) Gently push the module into the port For information about connecting an optical fiber, see "Connecting your switch to the network." Installing a CXP module CAUTION: •...
  • Page 32: Connecting A Cxp Fiber Cable

    • Read the following instructions before you connect a CXP fiber cable. Failure to follow these instructions might cause damage to the CXP fiber cable. • H3C provides only CXP AOC cables. CXP fiber cables are hot swappable. To connect a CXP fiber cable: Unpack the cable.
  • Page 33 • QSFP+ copper cable—Short distance transmission between QSFP+ ports. • QSFP+ to SFP+ copper cable—Short distance transmission between QSFP+ and SFP+ ports. • QSFP28 copper cable—Short distance transmission between QSFP28 ports. To connect an SFP+ copper cable, QSFP+ copper cable, or QSFP+ to SFP+ copper cable: Unpack the cable.