Enabling Power Supply Management - H3C S12508-AC Installation Manual

H3c s12500 routing switch series installation guide
Hide thumbs Also See for S12508-AC:
Table of Contents

Advertisement

MAC_ADDRESS
MANUFACTURING_DATE
VENDOR_NAME
# Display the electrical label information of power monitoring module 2 on member switch 1 in IRF
mode.
<Sysname> display device manuinfo chassis 1 power-monitor 2
Chassis 1:
Power Monitor unit 2:
DEVICE_NAME
DEVICE_SERIAL_NUMBER
MAC_ADDRESS
MANUFACTURING_DATE
VENDOR_NAME

Enabling power supply management

If power supply management is not enabled when you add a new card by inserting it into the slot or
starting power supply to the card by using the power-supply command, the system directly powers on the
card, and the power supply may become unstable or the system may restart because of overloading.
If power supply management is enabled when you add a new card by inserting it into the slot or starting
power supply to the card by using the power-supply command, the system compares the maximum
power consumption of the card against the available power (including the redundant power supply). If
the former is not greater than the latter, the system supplies power to the card, otherwise, the system does
not supply power to the card.
Follow these steps to enable power supply management:
To do...
Enter system view
Enable power supply management
(standalone mode)
Enable power supply management
on a specified member switch (IRF
mode)
Configuring the number of redundant power modules
Redundant power modules are reserved for power module backup and power module threshold
alarming. With multiple redundant power modules configured in the system, if a power module fails or
the system power supply is overloaded, the system automatically enables a redundant power module. As
a result, the number of redundant power modules decreases by one.
Follow these steps to configure the number of redundant power modules:
To do...
Enter system view
Enable power supply management
(standalone mode)
: NONE
: 2010-01-20
: H3C
: PMU2
: 210235A36L1234567891
: NONE
: 2010-01-20
: H3C
Use the command...
system-view
power-supply policy enable
power-supply policy enable
chassis chassis-number
Use the command...
system-view
power-supply policy enable
61
Remarks
Required
Enabled by default
Required
Enabled by default
Remarks
Required
Enabled by default

Hide quick links: