LED
Output
Service
Fault
Table 5 AC power module specifications
Item
Rated input voltage range
Max input voltage range
Max input current
Max output power
Power monitoring module
The power monitoring module (callout 7 in
operating status of the power modules in real time. It is located between the power module slot area and
the power switch.
PEM
The PEM (see
Figure 11 PEM location
Color
Status
On
Green
Off
Flashing
On
Yellow
Off
On
Red
Off
Description
100 VAC to 120 VAC/200 VAC to 240 VAC; 50 Hz or 60 Hz
90 VAC to 264 VAC; 47 Hz to 63 Hz
13.3 A
2000 W at 200 VAC to 240 VAC input
1200 W at 100 VAC to 120 VAC input
Figure 1
1) provides power to the power modules.
Description
Power is being correctly output.
No power is being output.
The power output is overloaded.
The AC power module is experiencing an over-temperature
condition.
The AC power module is operating properly.
The AC power module is faulty.
The AC power module is operating properly.
Figure
9) monitors the alarm status, in-position status, and