Safety data sheet for the Océ 9400-II Printer and Scanner
©1997 Océ-Technologies B.V.
The contents of this safety data sheet are subject to the disclaimer o n page145
of this manual.
Safety information
PRODUCT SAFETY DATA SHEET
Model
Description
Max. process speed
Dimensions
Width
Depth
Height
Weight
Voltage
Frequency
Current-rated
Current-max
Power consumption
Power consumption, stand by
EPA Energy Star®
* Power consumption,
sleep mode
Mains connection
Safety class
Protection class
Sound pressure level
(at bystander/operator
position)
Sound power level
Radio interference
Radiation
Heat emission
Ozone emission printer
Room volume
Room ventilation
Use simulation at random
operation
Consumables
Additional safety information
Listed according to standard
UL 1950
Océ 9400/9400-II Printer - Océ 9400/9400-II Scanner
Multifunction device, instant copying/printing, consisting of an electrostatic printer, console
model, plain paper, organic photoconductive drum, powder toner and a free standing
scanner, maximum original size 1020 mm x 3000 mm.
3 m/min
Printer
1 roll
2 roll
1352 mm
1352 mm
918 mm
918 mm
1251 mm
1251 mm
149 kg
159 kg
115 V
60 Hz
15 A
20 A
1500 W at continuous operation
46 W
49,2 W (printer + scanner). Default time 1 minute.
Cable with plug
I
(IEC 536) Protective earth connection
IP 20
(IEC 529)
Stand by
In operation
0 dB(A)
main body 51 dB(A)
impulse ∆ L
= 2 dB(A)
i
0 dB(A)
main body 61 dB(A)
Complies with FCC rules and regulations, part 15 class A
Below the Threshold Limit Values for UV, Visible and IR radiation (TLV list of ACGIH)
Printer 1500 W, scanner 90 W at continuous operation
0,02 mg/min at continuous operation
3
Recommendation: min. 25 m
3
Recommendation: min. 12,5 m
/h (natural ventilation)
With a room volume and ventilation as recommended and a daily volume of 100 m (much
more than average) the use simulation at random operation gives the following ozone
concentrations:
- Time weighted average
- Peak
Threshold Limit Value/Occupational Exposure Limit
(Time Weighted Average) for ozone
Odour Perception Limit for ozone
Océ OPC Drum (Océ Safety Data Sheet E-218)
Océ B4 Toner (Océ Safety Data Sheet E-196)
Océ D4 Developer (Océ Safety Data Sheet E-197)
Océ Copying Materials.
This apparatus is suitable for processing recycling paper. Ask Océ for suitable recycling
paper.
The ozone ?lter does not have to be replaced to keep the ozone concentration in the
3
workplace below 0,04 mg/m
(i.e. the life of the ?lter equals that of the apparatus).
Listed according to standard
CAN/CSA-C22.2 No. 950
Number
E-685-b-US
Date
March 1999
Scanner
1240 mm
615 mm
1105 mm
60 kg
115 V
60 Hz
1,1 A
2 A
90 W at continuous operation
3,2 W
Stand by
In operation
0 dB(A)
main body 48 dB(A)
impulse ∆ L
= 5 dB(A)
i
0 dB(A)
main body 60 dB(A)
3
0,002 mg/m
(0,001 ppm)
3
0,008 mg/m
(0,004 ppm)
3
0,2 mg/m
(0,1 ppm)
3
0,04 mg/m
(0,02 ppm)
EPA MFD Compliance