Power Capacity - Bosch DCN Next Generation Operation Manual

Table of Contents

Advertisement

78
en | Planning
4.2.3
Control capacity
Each device in the optical network has a number of nodes. The maximum number of nodes in
the optical network is 63.
Each device in the optical network has a certain delay that is represented with an equivalent
cable length. These values are important to be able to determine if optical network limit 3 is
not exceeded; refer to the sections Limits, page 77and Optical fiber length, page 80.
Device
DCN-CCU2 /
DCN-CCUB2
DCN-WAP
LBB4402/00
PRS-4DEX4
LBB4404/00
PRS-FINNA
PRS-NSP
LBB4419/00
INT-TX04
INT-TX08
INT-TX16
INT-TX32
Table 4.6: Nodes
4.2.4

Power capacity

It is important that the devices in the optical network do not use more total power than you
supply to the devices. Each device uses power and most devices do not have an independent
power supply.
Power consumption
The table shows the power each device in the optical network uses.
Device
LBB4402/00
LBB4404/00
PRS-NSP
PRS-FINNA
PRS-4DEX4
DCN-WAP
Table 4.7: Power consumptions
2013.11 | V2.0 | DCN-NG_OM_V4.x
Description
Central Control Unit
Wireless Access Point
Audio Expander Analog
Audio Expander Digital
Cobra Net Interface
Fiber Interface Non-Addressable
Network Splitter
Cable Couplers
Digital 4 Channel Integrus Transmitter
Digital 8 Channel Integrus Transmitter
Digital 16 Channel Integrus Transmitter
Digital 32 Channel Integrus Transmitter
Operation Manual
Nodes
2
1
1
1
1
0
1
0
1
2
4
8
Watt
7.6
10.5
3.9
4.6
6.0
4.0
Conference System
Equivalent cable
length (m)
24
18
18
18
18
16
34
20
18
24
36
59
Bosch Security Systems B.V.