Conference System
9.3

DCN-CON Concentus Unit

Problem
Bosch Security Systems B.V.
The displays of the Concentus unit(s)
show the start-up text.
Depending on menu setting 8L, the
microphone LED on top of the
loudspeaker of the Concentus delegate
units and Concentus chairman units is
flashing or continues red.
Languages displayed on the units do not
match with the languages set in the PC.
You can operate the units with their
buttons, but the units do not give an audio
signal to their loudspeakers or
headphones.
You cannot operate one or more units
with their buttons and: The system gives
power to the trunks, and the devices do
not give an audio signal to their
loudspeakers or headphones.
Hint
The contribution devices have the same
address. Make sure that each active device
in the DCN has a unique address (refer to
Initialization, page 178 and to DCN-CCU2
and DCN-CCUB2 Central Control Units,
page 183 > Double unitID).
Follow the instructions for downloading
(refer to Initialization, page 178).
The audio routing mode of the central
control unit is Insertion and you did not
connect a device between audio input 2
and audio output 2 of the central control
unit (refer to DCN-CCU2 and DCN-CCUB2
Central Control Units, page 183).
The DCN contains a defective extension
cable. Find the defective extension cable
and replace it. The defective extension
cable can be anywhere in the DCN.
Operation Manual
Troubleshooting | en
The DCN signal is re-generated too
many times (refer to DCN design, page
64).
The trunk is too long (refer to DCN
design, page 64).
The DCN signal is not re-generated
each 100 m (refer to DCN design,
page 64).
2013.11 | V2.0 | DCN-NG_OM_V4.x