Bosch DCN Next Generation Operation Manual page 243

Table of Contents

Advertisement

Conference System
Monitoring
Use the 2 Monitoring menu item to open the Monitoring sub-menu.
Menu item
2A Source/Volume
2B Input Engaged
Table 8.19: Monitoring sub-menu (* = default)
Bosch Security Systems B.V.
Parameter
Value
Audio input or
Volume level:
output:
In 1*
-31 to 0 dB (16 dB*)
In 2
-31 to 0 dB (16 dB*)
In 3
-31 to 0 dB (16 dB*)
In 4
-31 to 0 dB (16 dB*)
Out 1
-31 to 0 dB (16 dB*)
Out 2
-31 to 0 dB (16 dB*)
Out 3
-31 to 0 dB (16 dB*)
Out 4
-31 to 0 dB (16 dB*)
Audio input: 1, 2,
3, 4
Operation Manual
Operation | en
Description
The signal that is available
on the headphones socket
of the cobranet interface
and its volume level. The
menu item also shows the
attached channel (read-
only).
If the menu item shows a
audio input number in the
display, the language
channel corresponding with
the audio input is already in
use by another (digital)
audio expander, a cobranet
interface or an interpreter
desk.
2013.11 | V2.0 | DCN-NG_OM_V4.x
243

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents