Bosch DCN Next Generation Operation Manual page 287

Table of Contents

Advertisement

Conference System
11.2.31
LBB4416 Optical Network Cables
Insulation:
Outer diameter:
Power supply wires (2):
Optical fibers:
Temperature range:
Pull force:
Flame retardant:
Halogen level:
Smoke level:
11.2.32
DCN-DDB Data Distribution Board
External supply
Dimensions (H x W)
11.2.33
DCN-IDENC Chip Card Encoder
Dimensions (H x W x D)
Weight
Bosch Security Systems B.V.
LSZH (low smoke/zero halogen), black
7 mm
Copper, stranded 1 mm
resistance < 0.018 Ω/m
PMMA, 1 mm diameter includes cladding, 2
mm diameter includes insulation (black)
Numeric aperture: 0.5
Optical attenuation < 0.17 dB/m @ 650 nm
Bending loss < 0.5 dB (r = 20 mm, 90°),
according to JIS C6861
-40 to 65 °C
max. 150 N
According to IEC 60332-1 / 60 s
According to IEC 60754-2, pH > 4.3 and
conductivity < 10 uS/mm
According to IEC 61034-2, light transmittance >
60%
7.5 – 35 VDC.
100 x 200 mm (3.93 x 7.87 in)
90 x 70 x 16.5 mm (3.5 x 2.8 x 0.6 in)
145 g (0.3 lb)
Operation Manual
Technical Data | en
, red and brown insulation,
2
2013.11 | V2.0 | DCN-NG_OM_V4.x
287

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents