Bosch DCN Next Generation Operation Manual page 73

Table of Contents

Advertisement

Conference System
Socket
Trunk 1
Trunk 2
Trunk 3
Table 4.4: Example with conference units (DCN-CON)
The example above is within system limits because:
DCN-CCU2 or DCN-CCUB2 power correction
Type
Extension
Diagram
cable
DCN-
0 m
DISS
DCN-
100 m
DISS
DCN-
0 m
CON
DCN-
100 m
CON
DCN-
0 m
CONFF
Bosch Security Systems B.V.
Extension cable
35 m
20 m
10 m
DCN limit 1; maximum control capacity is not exceeded; this example contains only 65
active devices where 245 is the maximum.
DCN limit 2; maximum power capacity is not exceeded. The corrected power does not
exceed the maximum power of 85 W. The corrected power is however close to the
maximum, using longer extension cables or adding more conference devices, or trunk
splitters, will exceed the maximum a DCN socket can deliver.
DCN limit 3; maximum Loop-throughs of active or passive devices is not exceeded. The
limit is 25, the highest number of loop-throughs in this example is 6.
DCN limit 4; maximum tap-off connections is not exceeded. The limit is 4, the highest
number of loop-through connections in the example is 1.
DCN limit 5; maximum cable length is not exceeded. The limit is 250 m, the longest
distance from the central control unit to the furthest device in this example is only 51 m.
1
25 x 2 m
LBB4116
LBB4114
100 m
2 m
1
25 x 2 m
LBB4116
LBB4114
100 m
2 m
1
20 x 2 m
Power for devices
71.9 W
77.4 W
80.8 W
25
1
17
17 x 2 m
25
1
14
14 x 2 m
20
Operation Manual
Corrected power
84.2 W
84.4W
84.3W
Power for
devices
25 x 2.75
=
68.8 W
17 x 2.75
=
46.75 W
1 x 1.3
=
1.3 W +
48.05 W
25 x 3.4
=
85.0 W
14 x 3.4
=
47.6 W
1 x 1.3
=
1.3 W +
48.9 W
20 x 4.2
=
84.0 W
2013.11 | V2.0 | DCN-NG_OM_V4.x
Planning | en
73
Corrected
power
68.8 W
82.4 W
85.0W
83.8 W
84.0 W