Conference System
Menu item
8Ga Level
8Gb Routing I/O 2
Table 7.9: Audio I/O sub-menu (* = default)
Camera control
Use the menu item in the 8H Camera Cntrl sub-menu to select the type of connected camera
system.
Value
Autodome*
Allegiant
Table 7.10: Camera control sub-menu values (* = default)
IP address
Use the menu items in the 8I IP Address sub-menu to set the IP address.
Menu item
8Ia Address
8Ib Subnet Mask
8Ic Def. Gateway
Table 7.11: IP Address sub-menu (* = default)
CCU mode
Use the 8J CCU Mode sub-menu item to set the mode of the central control unit.
Bosch Security Systems B.V.
Parameter
Value
Signal:
Level:
Input 1*
-6 to 6 dB (0 dB*)
Input 2
-6 to 6 dB (0 dB*)
Output 1
-24 to 6 dB (0 dB*)
Output 2
-24 to 6 dB (0 dB*)
---
Multi slave mode:
Recorder*
Delegate Ldspkr
Local floor
Insertion or Int.
Floor insert
Stand alone, Single,
Multi Master Mode:
Recorder*
Delegate Ldspkr
Mix-Minus
Insertion, Int. Floor
insert or Insertion
no AGC
Description
The central control unit sends the camera control signal to a Bosch
Autodome (Baudrate 9.6 K).
The central control unit sends the camera control signal to a Bosch
Allegiant (Baudrate 19.2 K).
Value
Description
192.168.0.100 *
Sets the TCP/IP address.
255.255.255.0 *
Sets the TCP/IP subnet mask.
0.0.0.0 *
Sets the TCP/IP default gateway.
Operation Manual
Configuration | en
Description
The nominal levels of the
audio inputs and the audio
outputs of the central control
unit.
The audio routing mode of
the central control unit.
Refer to Audio I/O routing,
page 16.