7.16
DCN-EPS Extension Power Supply
Use the connector block inside the extension power supply to select the voltage on which the
extension power supply must operate.
Figure 7.26: Internal settings
Fuse T5A
Pin
105 V(AC)
1
Blue (power)
2
Black
3
Green
4
Orange
5
Blue
(transformer)
6
n.c.
7
Yellow
8
n.c.
9
Violet
10
Brown
Table 7.43: Internal settings (n.c. = not connected)
2013.11 | V2.0 | DCN-NG_OM_V4.x
10
9
8
7
6
5
4
3
2
1
115 V(AC)
125 V(AC)
n.c.
Blue (power)
Green
Green
Blue (power)
Black
Orange
Orange
Blue
Blue
(transformer)
(transformer)
Black
n.c.
Yellow
Yellow
n.c.
n.c.
Violet
Violet
Brown
Brown
Fuse T4A H
220 V(AC)
Blue (power)
Green
Green
n.c.
Blue
(transformer)
Violet
Yellow
Orange
n.c.
Brown
Operation Manual
Conference System
230 V(AC)
240 V(AC)
n.c.
Blue (power)
Green
Green
Black
Black
Blue
n.c.
Blue
Blue
(transformer)
(transformer)
Violet
Violet
Yellow
Yellow
Orange
Orange
n.c.
n.c.
Brown
Brown
Bosch Security Systems B.V.