Edge-Core ES3528MV2 Management Manual page 1192

Edge-core 28-port fast ethernet layer 2 switch
Table of Contents

Advertisement

| Quality of Service Commands
C
38
HAPTER
conform-action - Action to take when rate is within the CIR and
BC. (There are enough tokens in bucket BC to service the packet,
packet is set green).
exceed-action - Action to take when rate exceeds the CIR and BC
but is within the BE. (There are enough tokens in bucket BE to
service the packet, the packet is set yellow.)
violate-action - Action to take when rate exceeds the BE. (There
are not enough tokens in bucket BE to service the packet, the
packet is set red.)
transmit - Transmits without taking any action.
drop - Drops packet as required by exceed-action or violate-action.
new-dscp - Differentiated Service Code Point (DSCP) value.
(Range: 0-63)
D
S
EFAULT
ETTING
None
C
M
OMMAND
ODE
Policy Map Class Configuration
C
U
OMMAND
SAGE
You can configure up to 16 policers (i.e., class maps) for ingress ports.
The committed-rate cannot exceed the configured interface speed, and
the committed-burst and excess-burst cannot exceed 16 Mbytes.
The srTCM as defined in RFC 2697 meters a traffic stream and
processes its packets according to three traffic parameters –
Committed Information Rate (CIR), Committed Burst Size (BC), and
Excess Burst Size (BE).
The PHB label is composed of five bits, three bits for per-hop behavior,
and two bits for the color scheme used to control queue congestion. A
packet is marked green if it doesn't exceed the CIR and BC, yellow if it
does exceed the CIR and BC, but not the BE, and red otherwise.
The meter operates in one of two modes. In the color-blind mode, the
meter assumes that the packet stream is uncolored. In color-aware
mode the meter assumes that some preceding entity has pre-colored
the incoming packet stream so that each packet is either green, yellow,
or red. The marker (re)colors an IP packet according to the results of
the meter. The color is coded in the DS field [RFC 2474] of the packet.
The behavior of the meter is specified in terms of its mode and two
token buckets, C and E, which both share the common rate CIR. The
maximum size of the token bucket C is BC and the maximum size of the
token bucket E is BE.
– 1192 –

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Es3528mv2-dc

Table of Contents