User Manual
2.1.4 Harmonic Measurements (CSW series)
Parameter
Frequency fundamental
Frequency harmonics
Voltage
Current
Harmonics frequency range in three-phase mode is 32 Hz - 16 kHz. Measurement bandwidth is limited to 16 Khz.
CSW Series
Accuracy ( )
Range
16.00 - 1000 Hz
2 counts
32.00 Hz - 16 kHz
2 typ.
Fundamental
0.25V
Harmonic 2 - 50
0.25V + 0.1% + 0.1%/kHz
Fundamental
!% of Range
Harmonic 2 - 50
1% of Range + 0.1%/kHz
California Instruments
Resolution
0.01 Hz to 1 Hz
0.5
0.01V
0.01V
0.01A
0.01A
21