VOLT MAX
This test will change the output voltage from 28V or 14V to 30.3V or 15.1V. The test will last for
30 minutes. The  (backspace) will terminate the test at any time.
VOLT UNDER
This test applies to category Z and 28 volt category B equipment. The output voltage will drop to
10 volts and will ramp up at a rate of 0.15 volt/sec for the US standard and at a rate of 0.30
volt/sec for EUROCAE standard for 30 seconds before it returns to nominal value.
VOLT SURGE
This test will surge and sag the voltage to a level and duration specified Table 8-15 with 5
seconds between transients. The test is repeated three times.
Category
A
B
Z
POWER INTERRUPT
Refer to section POWER INTERRUPT.
136
Standard
A and Z
RTCA
30.3
EUROCAE
30.3

Table 8-14: Normal Voltage Maximum

Surge
Volt
Dwell(msec)
RTCA
EUR
40
40
40
40
50
50

Table 8-15: Voltage Surge

Categories
B 28V / 14V
30.3
29.3
Volt
US
EUR
30
15
17
30
15
17
50
12
12
California Instruments
15.1
14.6
Sags
Dwell(msec)
30
30
30
CSW Series