Table 8-16: Abnormal Voltage Surge - Ametek CSW5550 User Manual

Csw series ac power source
Table of Contents

Advertisement

User Manual
VOLT SURGE
This test will produce voltage surge defined by Table 8-16. This test will be repeated three times
with ten seconds intervals. The voltage values are halved for 14.0V category B equipment.
Category
A
B
Z
8.1.1.6.3 Emergency Test
The Emergency test is selected from the DO-160 DC Main Menu. This test will set the output
voltage to 18V for 28V equipment and to 9V for 14V equipment. The test will last for 30 minutes.
The  key (backspace) will terminate the test at any time.
138
Surge 1
Volt
Dwell(msec)
46.3
100
60
100
80
100

Table 8-16: Abnormal Voltage Surge

California Instruments
Surge 2
Volt
Dwell(msec)
37.8
1000
40
1000
48
1000
CSW Series

Hide quick links:

Advertisement

Table of Contents
loading