Number
Message String
-300
"Device specific error"
-311
"Memory error"
"Save/recall memory
-314
lost"
-315
"Configuration memory
lost"
-330
"Self-test failed"
-350
"Queue overflow"
-400
"Query error"
-410
"Query
INTERRUPTED"
-420
"Query
UNTERMINATED"
-430
"Query
DEADLOCKED"
-440
"Query
UNTERMINATED"
-831
"Lan connection
missing"
-831
"Duplicate IP, Set to
DHCP"
-832
"Duplicate IP, REM set
to reject"
-833
"Duplicate IP, LOC set
rejected"
-834
"Out of reach IP
1
"Output volt fault"
CSW Series
Cause
Remedy
Hardware related
Check hardware for proper operation.
error
Waveform memory
May be the result of incomplete user-
checksum error.
defined waveform download. Check
interface and try downloading
waveform again. Successful
download may clear this error
condition.
Alternatively, use TRAC:DEL:ALL
command to clear waveform memory.
User setup register
Store setup in same register again.
contents lost
Hardware
Contact CI service department at
configuration settings
support@calinst.com
lost.
instructions on restoring configuration
data.
Internal error
Contact CI service department at
support@calinst.com
Message queue full.
Too many message. Read status
using SYST:ERR query until 0, "No
Error" is received indicating queue
empty.
Unable to complete
Check programming manual for
query.
correct query format and parameters
Query issued but
Check application program for correct
response not read.
flow. Response must be read after
each query to avoid this error.
Query incomplete.
Check for terminator after query
command.
Query cannot be
Check application program for
completed
multiple queries
Query incomplete.
Check for terminator after query
command.
Output voltage does
Load exceeds current limit and unit is
not match
in Constant Voltage (CV) mode of
programmed value.
operation. Reduce load or increase
CL setting
Output voltage is driven above
programmed voltage by external
influence (Load, voltage kickback,
etc.)
California Instruments
to obtain
177