6.3.8 Distorted Output
CAUSE
Power source is grossly overloaded.
The crest factor of the load exceeds 3:1 on
the low range or 5:1 on the high range.
6.3.9 No Output and No Lights on Front Panel
CAUSE
Input circuit breaker switched off.
No AC Line input power to TB1.
Circuit Breaker tripped for overvoltage or
over current.
120
SOLUTION
Reduce load
Reduce load current peaks by reducing
load.
SOLUTION
Switch the breaker on.
Ensure 3 phase power is getting to TB1.
Turn circuit breaker off - wait five seconds
- turn circuit breaker back on. If breaker
trips again measure the AC line input
California Instruments