Whm Option; Figure 8-43: Application Screen; Figure 8-44 Watt-Hour Meter Screen; Figure 8-45: Wh-Meter Screen With Function Active - Ametek CSW5550 User Manual

Csw series ac power source
Table of Contents

Advertisement

User Manual

8.9 WHM Option

8.9.1 General
This section describes the WHM option for the CSW Series Power Source.
8.9.2 Specification
All specifications are the same as the standard CSW Power Source specifications in addition to
the following specifications:
Watt-hour
0-6.000KW
>6.000KW
8.9.3 Local Operation
From the Menu screen 2, select the APPLICATIONS SETUP 2 screen. The screen will appear
as shown in Figure 8-43. Use the up and down key to position the cursor to the WH METER
field. Press the Enter Key.
The WATT-HOURS METER screen shown in Figure 8-44 has the following fields:
START: This field will activate the watt-hour measurements. Moving the shuttle clockwise when
the field is highlighted will activate the watt hour function and the field will change to STOP as
shown in Figure 8-45.
1. ETIME: This field will accumulate the time in hours, minutes and seconds.
2. WATT HR: This field will accumulate the watt-hour in KWH.
3. POWER: This field will report the instantaneous power in KW.
4. PK CURR: This field will report the peak current and will hold the maximum reading.
172
0.01KWH + 0.1% <100Hz
0.02KWH +0.1% 100-500Hz
Times three of the above specification

Figure 8-43: Application Screen

Figure 8-44 Watt-Hour Meter Screen

Figure 8-45: WH-Meter Screen With Function Active

California Instruments
CSW Series

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents