Appendix C: Error Messages

Error Number
0
-100
-200
-300
-350
-400
Error Message String
"No error"
"Command error"
"Execution error"
"Device specific error"
"Queue overflow"
"Query error"

Table 12-1: Bus Error Messages

California Instruments
Error Causes
Generally the result of sending a
command that uses incorrect syntax.
This same error may result from the
inability of the AC source to process
successive GPIB non-query commands
sent to it. To avoid this condition, it is
necessary for the application
programmer to insert a 20 msec delay
between commands.
Generally the result of sending a value
that is out of range, i.e., a VOLT 200
command when the unit is in the 135 V
(Low) range.
Generally the result of an over current
(current limit trip) or over temperature
condition.
Generally caused by too many errors
being generated without reading error
status, causing error buffer to overflow.
Generally caused by sending a query
followed by another command without
accepting the query response first.