Ametek CSW5550 User Manual page 178

Csw series ac power source
Table of Contents

Advertisement

User Manual
Number
Message String
2
"Current limit fault"
3
"Temperature fault"
4
"External sync. error"
5
"Initial memory lost"
6
"Limit memory lost"
7
"System memory lost"
8
"Calibration memory
lost"
"Start angle must be
9
first sequence"
10
"Illegal for DC"
11
"Duplicate sequence"
12
"Too many sequence"
13
"Missing list
parameter"
14
"Voltage peak error "
16
"Illegal during
transient"
17
"Output relay must be
closed"
18
"Trans. duration less
then 1msec"
19
"Clock and sync must
be internal"
20
"Input buffer full"
178
Cause
Remedy
Current limit
Load exceeds current limit and unit is
exceeded.
in Constant Voltage (CV) mode of
operation. Reduce load or increase
CL setting
Temperature of heat
Reduce load. Ensure proper air flow
sink too high.
and exhaust clearance. Check fan(s)
for operation.
Could not sync to
External sync signal missing,
external sync signal.
disconnected or out of range.
Power on settings
Save power on settings again to
could not be recalled.
overwrite old content.
Hardware
Contact CI service department at
configuration settings
support@calinst.com
lost.
instructions on restoring configuration
data.
Memory corrupted.
Recycle power.
Calibration data lost.
Contact CI service department at
support@calinst.com
instructions on restoring calibration
data or recalibrate unit.
Start phase angle in
Start phase angles can only
wrong place..
programmed at the start of a transient
list. Once a transient is in progress,
phase angle cannot be changed.
Operation not
Switch to AC or AC+DC mode.
possible in DC mode.
N/A
N/A
N/A
N/A
One or more
Check programmed lists.
transient list
parameters missing.
Peak voltage
This error may occur when selecting
exceeds internal bus
user defined wave shapes with higher
voltage
crest factors. Reduce programmed
RMS value.
Operation requested
Wait till transient execution is
not available while
completed or abort transient
transient is running.
execution first.
Operation not
Close relay before attempting
possible with open
operation. E.g. transient execution
relay
requires output relay to be closed.
Dwell time below
Increase dwell time to at least 1
minimum or 1 msec
msec.
Operation not
Switch to internal sync. (Default)
possible with external
clock
Too much data
Break up data in smaller blocks.
received.