Reference Pen Conditions for Plotting Pens
Pen type
Water based fiber-tip pen
To preserve the pen's longevity, set the FORCE to the lowest possible setting that permits you to obtain
the desired plotted results. Set the SPEED after checking the plotted results for the absence of faint
lines and other problems.
NOTE : • If the SPEED and QUALITY are set to high values, the cut/plotted results have a
coarser finish but the overall cutting/plotting time is shortened.
• If the SPEED and QUALITY settings are set to low values, the cut/plotted results
have a finer finish but the overall cutting/plotting time is longer.

4.4.1 Selecting a Set of Cutting Conditions

Four different sets of user-defined cutting conditions can be registered in the plotter's memory as COND
Nos. 1 through 4. To specify a set of cutting conditions, you must first select the destination COND No. By
selecting a different COND No., you can easily switch between pre-defined cutting conditions for four types
of media.
1
Step
Each time you press the
changed from COND1 through COND4. Pressing the
the setting back to COND1.
COND1
==
READY
2
Step
The currently selected blade type, CUTTER OFFSET, and FORCE settings appear. When the blade
type setting is PEN, the CUTTER OFFSET setting does not appear. When the blade type setting is
OTHER, an asterisk symbol (∗) appears in place of the blade type.
The blade type setting appears
here as 09U, 15U, PEN, or
(the asterisk represents the
OTHER setting).
COND1
==
READY
FORCE
10 to 12
key at the menu below, the selected set of cutting conditions is sequentially
NEXT PAGE
PEN
12
==
The blade's CUTTER OFFSET
setting appears here.
No setting is displayed when
the blade type setting is PEN.
PEN
12
The cutting FORCE setting appears here.
==
SPEED
QUALITY
30
2