sequence on noread:
0 = disabled
1 = enabled
When disabled, the scanner does not sequence
(increment or decrement) on a noread.
When enabled, the scanner sequences on every
noread.
sequence on every mismatch:
0 = disabled
1 = enabled
When disabled, if a mismatch is out of sequence
by no more than 1, then the sequence resumes
and searches indefinitely.
When enabled, the scanner sequences on
every mismatch.
Example: To enable Match Code Type for Sequential, set Sequential Matching for
Decrement, and enable Sequence on Every Mismatch, enter <Kn2,1,,,,,1>.
Number of Labels
Format: <KLnumber of labels,field separator>
number of labels:
0 = One label
3 = Four labels
1 = Two labels
4 = Five labels
2 = Three labels 5 = Six labels
Example: To set Number of Labels to four labels with a dash (-) for a Field Separa-
tor, enter <KL3,->.
Trigger Filter Timing Value
Format: <KF?>
Returns the current trigger filter timing value in milliseconds.
Format: <KFone tenth trigger filter timing value>
Allows you to set trigger filter timing. Divide the desired number of millisec-
onds by 10 and enter the quotient.
Operations Status Request
Format: <KG?2>
Returns status of each command in the group.
MS-7100/7180 Industrial Scanner User's Manual
Operations Commands
If 001, 002, noread, then
search for 003.
If 001, 002, noread, then
search for 004.
a
If 001, 002,
004 (mismatch), then
search for 005.
If 001, 002, mismatch, then
search for 004. If mismatch
occurs again, then search for
005, etc.
field separator:
Any ASCII character, except a NUL.
Default is a comma (
,
).
3-11
Need help?
Do you have a question about the MS-7100 and is the answer not in the manual?