9/ Starting UP

9.1. Before Starting

Before connecting the KBox A-151-TGL to power, read the instructions in this user guide and observe the safety
instructions in Chapter 2/General Safety Instructions.
The product comes hardware configured and on request with a pre-installed Operating System (OS) and all the
necessary drivers (in accordance with the ordered hardware configuration). No further internal configuration is
required, enabling full operation when connected to power and switched on for the first time.
Operated in closed condition only
It is only ensured that users do not have access to internal components during operation if
the product is closed and secured.
Only connect the product to an external power supply providing the voltage type (AC or DC)
and the input power (max. current) specified on the Kontron Product Label and meeting the
requirements of the Limited Power Source (LPS) and Power Source (PS2) of UL/IEC 62368-1.
Ensure that the power supply and power cables have no visible damage.
9.1.1.

Wiring the Power IN Connector

The Power IN connector connects to a DC power supply using the supplied mating power connector (PSC 1.5/ 3-F) and
the corresponding wiring inserted into the mating power connector's clamps (Figure 17, pos. 4, 5 & 6). Mark the supply
wires (+/-) clearly to ensure a safe connection from the Power IN connector to the DC power supply.
The wiring is not part of the delivery and must be provided by the user.
Use copper conductors only if the field wiring terminal is only for connection to copper wire.
Minimum temperature rating of the field wiring terminals is 75° C.

Figure 17: Power IN Connector and Mating Power Connector

1
3-pin Power IN connector (PSC 1.5/ 3-M)
2
3-pin mating power connector (PSC 1.5/ 3-F)
3
Cover over the slotted pan head screws
www.kontron.com
1
KBox A-151-TGL - User Guide Rev. 1.0
2
5
4
6
4
Clamp for earth wire
5
Clamp for 0 VDC wire
6
Clamp for +24 VDC wire
3