Troubleshooting; Service Call Conditions - Ricoh B089 Service Manual

Hide thumbs Also See for B089:
Table of Contents

Advertisement

7. TROUBLESHOOTING

CAUTION
Never turn off the main power switch when the power LED is lit or flashing.
To avoid damaging the hard disk or memory, press the operation power
switch to switch the power off, wait for the power LED to go off, and then
switch the main power switch off.
NOTE: The main power LED (
ARDF is open, while the main machine is communicating with a facsimile
or the network server, or while the machine is accessing the hard disk or
memory for reading or writing data.

7.1 SERVICE CALL CONDITIONS

7.1.1 SUMMARY
There are 4 levels of service call conditions.
Level
To prevent damage to the machine, the main
machine cannot be operated until the SC has
A
been reset by a service representative (see the
note below).
SCs that disable only the features that use the
defective item. Although these SCs are not
B
shown to the user under normal conditions,
they are displayed on the operation panel only
when the defective feature is selected.
The SC history is updated. The machine can be
C
operated as usual.
Turning the main switch off then on resets SCs
D
displayed on the operation panel. These are re-
displayed if the error occurs again.
NOTE: 1) If the problem concerns electrical circuit boards, first disconnect then
reconnect the connectors before replacing the PCBs.
2) If the problem concerns a motor lock, first check the mechanical load
before replacing motors or sensors.
SM
) lights or flashes while the platen cover or
Definition
7-1
SERVICE CALL CONDITIONS
Reset Procedure
Enter SP mode, and then turn
the main power switch off and
on.
Turn the operation switch or
main switch off and on.
The SC will not be displayed.
Only the SC history is updated.
Turn the operation switch off
and on.
B089/B093

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B093B08Aficio 2022Aficio 2027

Table of Contents